Fog or condensation trapped between the panes means the sealed unit has failed. It cannot be cleaned out. The repair is a new insulating unit glazed into the existing frame.

Call (619) 782-6663 Free estimate

Two panes with a fogged cavity shown as a dark teal window study

Why does a sealed unit fog and stay fogged?

A double-pane unit is two panes held apart by a spacer that contains desiccant, all sealed around the perimeter. The trapped air or gas in the cavity is dry by design, so no condensation forms. When the perimeter seal fails, outside air carrying water vapour enters the cavity. The desiccant absorbs it until it is saturated, and from then on the moisture condenses on whichever pane is colder. That is the fog you see at the edges first and across the whole unit later. It is inside the sealed assembly, which is why wiping, drilling or venting does nothing except break the seal further. The unit is finished once this happens, and the only real repair is replacement of the insulated glass.

Does the window frame have to be replaced too?

In most cases no, and that is the point of a re-glaze. The frame, the sash, the hardware and the surrounding wall all stay where they are; only the sealed unit is measured and replaced. On aluminium or vinyl frames that are square and sound, this is straightforward and keeps the original trim and stucco line. It becomes a replacement rather than a re-glaze when the frame has bowed, when the sash has separated at the corner, or when water has reached the frame through the failed seal and softened the sill. Those conditions are checked before the unit is ordered, because a new sealed unit set into a failing frame is money spent twice.

What do low-emissivity and gas fill actually do?

Two things make an insulated unit perform: the coating on the glass and what is inside the cavity. A low-emissivity coating reflects long-wave heat back into the room in winter and reduces solar gain in summer, depending on which surface it is applied to and how it is specified. An argon or krypton fill replaces air in the cavity, and because those gases conduct less heat the unit insulates better than an air-filled one of the same thickness. Neither lasts forever: a failed seal lets the gas escape and moisture in, which is why the seal quality matters more than the headline specification. A cheap unit with a poor spacer will fog again long before a good one.

Why is the spacer the part that decides how long it lasts?

The spacer is a small component with a large job. It holds the panes at the correct gap, contains the desiccant, and forms the primary seal with the butyl and then the secondary sealant at the perimeter. Warm-edge spacer designs reduce the thermal bridge at the edge of the glass, which cuts condensation on the frame in cold weather. Metal box spacers conduct more heat and are more prone to edge condensation. The difference shows up years later, as a window that stays clear and a frame that stays dry, versus one that fogs and grows mould in the corners. It is worth asking what spacer is in a unit rather than only what the U-value is.

Get a written figure for this job

Sealed unit work is quoted per unit against the measured opening, because the rebate and glass thickness have to match exactly. Tell us which windows have fogged and when it started, and the visit confirms the frame is still sound before a unit is ordered.

Call (619) 782-6663 Request an estimate

How is the replacement carried out?

The failed unit is measured in the frame rather than ordered from a nominal size, because the opening, the rebate and the glass thickness all have to match. The sash or frame is freed, the old unit removed carefully, and the rebate cleaned of old sealant and any corrosion. New setting blocks go in to hold the unit off the frame at the correct points, the new sealed unit is set, and either a glazing bead or a wet seal is restored depending on the frame type. The window is checked for operation and the perimeter for seal before the job is finished. The old unit leaves with the technician rather than going into your bin.

Does a fogged unit affect anything other than appearance?

It does, in three ways that are easy to overlook. The obvious one is that you cannot see through it, which is a nuisance in a bedroom or a view window but a genuine safety issue on a door or a low window. The second is thermal: a failed unit has lost the insulating cavity, so that window becomes a cold surface in winter and a heat path in summer, and the room behaves like it has a single pane in that opening. The third is moisture. A unit that has taken in water can hold it against the frame and the rebate, and over time that shows up as corrosion at the aluminium, mould in the corners, and eventually a soft sill. Fixing a fogged unit early is therefore cheap maintenance, not cosmetic spending.

How long should a sealed unit reasonably last?

There is no single answer, because the seal is a manufactured component with a service life that depends on the spacer, the sealant, the climate and how the window is exposed. Units on the sun-baked west elevation of an inland house work harder than the same product on a shaded north wall. What is fair to say is that a well-made unit with a warm-edge spacer will typically outlast a cheap metal-box unit in the same opening, and that a unit failing within a few years points to a measurement or installation fault rather than normal wear. That is why a replacement unit is measured to the opening and set on proper blocks instead of being ordered to an approximate size and forced into the rebate.

Common questions

Can fogged double pane glass be repaired without replacing the unit?

No. The moisture is inside the sealed cavity and the desiccant is saturated, so no cleaning or drilling restores it. Anything that breaks the seal to let the moisture out also lets more moisture in. Replacing the insulated unit is the only real repair.

Is it cheaper to replace the glass or the whole window?

Replacing the insulated unit is far cheaper than a whole window whenever the frame and sash are sound. A full window only becomes the better answer when the frame has bowed, rotted or separated, which is checked before anything is ordered.

Why did only one pane fog when the others are fine?

Seals fail individually, usually because of a defect at the perimeter, thermal stress on a sun-exposed elevation, or movement in the frame. One failed unit does not mean the others will follow, though units from the same batch fitted on the same elevation tend to age similarly.

Will a new unit fog again?

It can, eventually, because every seal has a service life. A better spacer and a correctly set unit with proper setting blocks reduce the risk substantially. What should not happen is a unit that fogs within a year or two, which points to a measurement or installation fault.